Skip to main content

How to Access MOODLE in Intranet and Internet

When Moodle is accessed either in Intranet or internet, there will not be any issue. But occasions when the MOODLE Site has to be accessed both in the intranet and in the Internet, here is a simple trick
Server Used: IBM Blade Servers
Operating system: Windows Server 2008
Moodle Version: 2.4
WAMP Server is used.
Number of Users: 3000 (Students) + 200 (Faculty)
Open the config.php from ~/moodle/config.php
include these lines
$CFG->wwwroot = 'http://'.$server_id.'/vitcc';
$CFG->dataroot  = 'C:\\wamp\\moodledata';
before the following line
$CFG->directorypermissions = 07xx;
Restart the WAMP Server and you can Check MOODLE Site both in Internet and Intranet.

The above Image tells the intranet Link and the internet link can be opened outside the campus network

Comments

  1. I have installed Moodle server in Ubuntu 20. 04 LTS.

    I want to access my server from my college LAN & Outside through internet.

    We have dedicated public IPs available.

    How can I configure internal and external access . We have college website https://cce.edu.in
    I want to access Moodle server "moodle. cce.edu.in"

    ReplyDelete

Post a comment

Popular posts from this blog

Installing TexLive 2019 in Ubuntu 18.04

Installation of TexLive 2019 in Linux (Ubuntu 18.04 LTS)
TeX (Tech)

Installation of TexLive 2019

Please watch the video for full installation



I used .iso file to download, the Total size is 3.3GB for Linux,

and i used the torrent file to download, it took me just 20 min to download the entire .iso file

Extract the .iso file to a folder and open a terminal

$] sudo ./install-tl
(it goes into a terminal mode, which is faster compared to the GUI Mode)

$] sudo ./install-tl -gui
after the installation, set the PATH, MANPATH and INFOPATH as suggested by LATEX

export PATH=$PATH:/usr/local/texlive/2019/bin/x86_64-linux
export MANPATH=/usr/local/texlive/2019/texmf-dist/doc/man
export INFOPATH=/usr/local/texlive/2019/texmf-dist/doc/info

put these lines in to the /home/pradeepkumar/.bashrc

$] gedit /home/pradeepkumar/.bashrc
We have installed TexLive 2019 and texstudio.

To install texstudio

$] sudo apt install texstudio
The look and feel of TexStudio looks like this image.


texlive, it install everyt…

Implementing a new system call in Kernel version 2.6.32

A system call is used by application or user programs to request service from the operating systems. Since the user programs does not have direct access to the kernel whereas the OS has the direct access. OS can access the hardware through system calls only.The following files has to be modified for implementing a system call/usr/src/linux-2.6.32.5/arch/x86/kernel/syscall_table_32.S/usr/src/linux-2.6.32.5/arch/x86/include/asm/unistd_32.h/usr/src/linux-2.6.32.5/include/linux/syscalls.h/usr/src/linux-2.6.32.5/MakefileNew set of files to be createdCreate a new directory newcall/ inside the path “/usr/src/linux-2.6.32.5/” Create new files Makefile, newcall.c and put them in the /usr/src/linux-2.6.32.5/newcall/ folder Create new user files (in any folder of Linux) to test the system call
testnewcall.c, testnewcall.h (created in /home/pradeepkumar) syscall_table_32.S Find the file /usr/src/linux-2.6.32.5/arch/x86/kernel/syscall_table_32.S and add the following line at the end
"…

Electrical Machine Design (equations)

FactorsDC Machine Transformers Induction Machines Synchronous MachinesOutput EquationPa=CoD2Ln, where Pa=P/h for generators, Pa=P for motorsFor Single Phase
Q=2.22 f Bm Ai Kw Aw d10-3
For Three Phase
Q=3.33 f Bm Ai Kw Aw d 10-3Q=CoD2 L ns
KVA Input Q=
HP * 0.746 / Cos f * hQ=CoD2 L ns
KVA Input Q=
HP * 0.746 / Cos f * h
For Turbo alternators
Q=1.11Bavac KwsVa2 L 10-3/nsOutput CoefficientCo=Bav ac* 10-3where Bav-magnetic loading and ac - electric loadingDNACo=11 Kws Bav ac 10-3Co=11 Kws Bav ac 10-3 Choice of Magnetic LoadingFlux Density in Teeth Frequency of Flux Reversals Size of machineDNAMagnetizing current, Flux Density, Iron lossIron loss, Stability, Voltage Rating, Parallel Operation, Transient ShortCircuit current Choice of Electric LoadingTemperature rise,
speed of machine, Voltage, Armature reaction, CommutationDNAOverload Capacity, Copper losses, Temperature rise, Leakage ReactanceCopper loss, Synchronous reactance, Temperature rise, Stray Load losses,
Voltage rating Flux …