Skip to main content

How to make boot entry in CentOS for Windows 10

Whenever you try installing Cent OS, after the installation of CentOS, the windows 10  or windows 8 might have gone missing from the boot table entry.
This is due to one of the reasons
  • Since Windows 10 or 8 runs with NTFS filesystem which could not be understandable by Cent OS
  • any other booting issues like UEFI or GPT partition issues.
Any how, one can try the first method to get rid of the NTFS filesystem issue.

After installing CEntOS, get it in to the Cent OS and open the terminal and give the command one by one

$] sudo yum install epel-release
or
$] sudo yum install epel-release.noarch

$] sudo yum install ntfs-3g

Depending on the speed of the internet, the above command might take some time to install.

$] sudo grub2-mkconfig > /dev/null

this command will read the windows 10 or 8 partition. Thats it. Reboot the machine and you can boot in to Windows 10.

Here is the image
CentOS

  and final step is here, execute these commands
$] sudo grub2-mkconfig -o /boot/grub2/grub.cfg

If EFI Mode is enabled, then issue this command

$]  sudo grub2-mkconfig -o /boot/efi/EFI/centos/grub.cfg

Comments

Popular posts from this blog

Installing TexLive 2019 in Ubuntu 18.04

Installation of TexLive 2019 in Linux (Ubuntu 18.04 LTS)
TeX (Tech)

Installation of TexLive 2019

Please watch the video for full installation



I used .iso file to download, the Total size is 3.3GB for Linux,

and i used the torrent file to download, it took me just 20 min to download the entire .iso file

Extract the .iso file to a folder and open a terminal

$] sudo ./install-tl
(it goes into a terminal mode, which is faster compared to the GUI Mode)

$] sudo ./install-tl -gui
after the installation, set the PATH, MANPATH and INFOPATH as suggested by LATEX

export PATH=$PATH:/usr/local/texlive/2019/bin/x86_64-linux
export MANPATH=/usr/local/texlive/2019/texmf-dist/doc/man
export INFOPATH=/usr/local/texlive/2019/texmf-dist/doc/info

put these lines in to the /home/pradeepkumar/.bashrc

$] gedit /home/pradeepkumar/.bashrc
We have installed TexLive 2019 and texstudio.

To install texstudio

$] sudo apt install texstudio
The look and feel of TexStudio looks like this image.


texlive, it install everyt…

Implementing a new system call in Kernel version 2.6.32

A system call is used by application or user programs to request service from the operating systems. Since the user programs does not have direct access to the kernel whereas the OS has the direct access. OS can access the hardware through system calls only.The following files has to be modified for implementing a system call/usr/src/linux-2.6.32.5/arch/x86/kernel/syscall_table_32.S/usr/src/linux-2.6.32.5/arch/x86/include/asm/unistd_32.h/usr/src/linux-2.6.32.5/include/linux/syscalls.h/usr/src/linux-2.6.32.5/MakefileNew set of files to be createdCreate a new directory newcall/ inside the path “/usr/src/linux-2.6.32.5/” Create new files Makefile, newcall.c and put them in the /usr/src/linux-2.6.32.5/newcall/ folder Create new user files (in any folder of Linux) to test the system call
testnewcall.c, testnewcall.h (created in /home/pradeepkumar) syscall_table_32.S Find the file /usr/src/linux-2.6.32.5/arch/x86/kernel/syscall_table_32.S and add the following line at the end
"…

Electrical Machine Design (equations)

FactorsDC Machine Transformers Induction Machines Synchronous MachinesOutput EquationPa=CoD2Ln, where Pa=P/h for generators, Pa=P for motorsFor Single Phase
Q=2.22 f Bm Ai Kw Aw d10-3
For Three Phase
Q=3.33 f Bm Ai Kw Aw d 10-3Q=CoD2 L ns
KVA Input Q=
HP * 0.746 / Cos f * hQ=CoD2 L ns
KVA Input Q=
HP * 0.746 / Cos f * h
For Turbo alternators
Q=1.11Bavac KwsVa2 L 10-3/nsOutput CoefficientCo=Bav ac* 10-3where Bav-magnetic loading and ac - electric loadingDNACo=11 Kws Bav ac 10-3Co=11 Kws Bav ac 10-3 Choice of Magnetic LoadingFlux Density in Teeth Frequency of Flux Reversals Size of machineDNAMagnetizing current, Flux Density, Iron lossIron loss, Stability, Voltage Rating, Parallel Operation, Transient ShortCircuit current Choice of Electric LoadingTemperature rise,
speed of machine, Voltage, Armature reaction, CommutationDNAOverload Capacity, Copper losses, Temperature rise, Leakage ReactanceCopper loss, Synchronous reactance, Temperature rise, Stray Load losses,
Voltage rating Flux …