Skip to main content

Active HDL 7.2 Student Edition for VHDL

If you are a student and if you want to design digital circuits and to learn VHDL/Verilog, then download the Active HDL 7.2 Student Edition. The Size of the file comes around 140MB.

Install as per the recommended settings. Once installed, without license file the application wont open. You need to register to get the license file. The file would be sent to our email Id or directly after registration we can download the file in the web page itself. The license file is applicable only for that machine. If the software has to be installed on another machine, another license you need to download.

Copy the license_student.dat file in the following folder C:\Program Files\Aldec\Active-HDL 7.2SE\Dat. And now the application can be opened and digital circuits can be simulated

Comments

  1. is it compatiable with windows7??

    ReplyDelete
  2. plz send free software

    ReplyDelete
  3. sir
    please send me 'active hdl software for student purpose.

    ReplyDelete
  4. hi i have the license key but also active vhdl is unable to open
    can u plz tel me hw can i start the active vhdl

    ReplyDelete
  5. shailendra singh24 May 2011 at 19:35

    i am a student doing phd in vlsi design...need active hdl

    ReplyDelete
  6. i want vhdl software ....actually i'm doing my training in vhdl

    ReplyDelete
  7. sandeep , you can download the software from the link, that i have provided...

    ReplyDelete
  8. please mail me the link too

    ReplyDelete
  9. sir please tell me about active hdl 7.2 in ubuntu
    i have installed it in windows 7 but i want to install active hdl 7.2 in ubuntu 11.04

    ReplyDelete
  10. where is the link to download?

    ReplyDelete
  11. Dear sir
    please send me ‘active hdl software for student purpose.

    ReplyDelete
  12. sir i tried but its not working its saying that you have 20 days to register..... but i have registered it ...... plzzz help sir

    ReplyDelete
  13. Did you tried copying the license.dat in the specified folder. if not do it.

    ReplyDelete
  14. sir can u pls provide us the link.. i didnt find the link sir..

    ReplyDelete
  15. http://72.55.168.40/Products/Evaluation.aspx?productevaluationid=da3b4fe8-427d-4945-919d-53bd8eef6d27

    ReplyDelete

Post a comment

Popular posts from this blog

Implementing a new system call in Kernel version 2.6.32

A system call is used by application or user programs to request service from the operating systems. Since the user programs does not have direct access to the kernel whereas the OS has the direct access. OS can access the hardware through system calls only. The following files has to be modified for implementing a system call /usr/src/linux-2.6.32.5/arch/x86/kernel/syscall_table_32.S /usr/src/linux-2.6.32.5/arch/x86/include/asm/unistd_32.h /usr/src/linux-2.6.32.5/include/linux/syscalls.h /usr/src/linux-2.6.32.5/Makefile New set of files to be created Create a new directory newcall/ inside the path “ /usr/src/linux-2.6.32.5/ ” Create new files Makefile, newcall.c and put them in the /usr/src/linux-2.6.32.5/newcall/ folder Create new user files (in any folder of Linux) to test the system call testnewcall.c, testnewcall.h (created in /home/pradeepkumar ) syscall_table_32.S Find the file /usr/src/linux-2.6.32.5/arch/x86/kernel/syscall_tab

How to Access MOODLE in Intranet and Internet

When Moodle is accessed either in Intranet or internet, there will not be any issue. But occasions when the MOODLE Site has to be accessed both in the intranet and in the Internet, here is a simple trick Server Used: IBM Blade Servers Operating system: Windows Server 2008 Moodle Version: 2.4 WAMP Server is used. Number of Users: 3000 (Students) + 200 (Faculty) Open the config.php from ~/moodle/config.php include these lines $CFG->wwwroot = 'http://'.$server_id.'/vitcc'; $CFG->dataroot  = 'C:\\wamp\\moodledata'; before the following line $CFG->directorypermissions = 07xx; Restart the WAMP Server and you can Check MOODLE Site both in Internet and Intranet. The above Image tells the intranet Link and the internet link can be opened outside the campus network

Electrical Machine Design (equations)

Factors DC Machine Transformers Induction Machines Synchronous Machines Output Equation P a =C o D 2 Ln, where Pa=P/h for generators, Pa=P for motors For Single Phase Q=2.22 f B m A i K w A w d 10 -3 For Three Phase Q=3.33 f B m A i K w A w d 10 -3 Q=C o D 2 L n s KVA Input Q= HP * 0.746 / Cos f * h Q=C o D 2 L n s KVA Input Q= HP * 0.746 / Cos f * h For Turbo alternators Q=1.11B av ac K ws V a 2 L 10 -3 /n s Output Coefficient C o =B av ac* 10 -3 where Bav-magnetic loading and ac - electric loading DNA C o =11 K ws B av ac 10 -3 C o =11 K ws B av ac 10 -3 Choice of Magnetic Loading Flux Density in Teeth Frequency of Flux Reversals Size of machine DNA Magnetizing current, Flux Density, Iron loss Iron loss, Stability, Voltage Rating, Parallel Operation, Transient ShortCircuit current